-40%

Fluke Calibration 1504-156 Tweener Thermometer Readout

$ 1654.19

Availability: 100 in stock
  • UPC: 095969120234
  • Condition: New
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Brand: Fluke Calibration
  • Item must be returned within: 30 Days
  • Return shipping will be paid by: Buyer
  • All returns accepted: Returns Accepted
  • MPN: 1504-156

    Description

    Subscribe to Our Newsletter
    Fluke Calibration 1504-156 Tweener Thermometer Readout for Thermistor Probes
    Brand:
    Fluke Calibration
    Model No:
    1504-156
    Ref No:
    1648966
    Our Model No:
    1504156
    Product Overview
    Features
    Temperature range: Any thermistor range
    Resistance range: 0Ohm to 1MOhm, auto-ranging
    Probe: Thermistors
    Resistance accuracy (ppm of reading):0Ohm to 5 KOhm: 0.5Ohm; 5 KOhm to 200 KOhm: 100 ppm; 200 KOhm to 1 MOhm: 300 ppm
    Temperature accuracy: ±0.002 °C at 0 °C; ±0.002 °C at 25 °C; ±0.004 °C at 50 °C; ±0.010 °C at 75 °C; ±0.020 °C at 100 °C
    Description
    The Fluke Calibration 1504-156 Tweener Thermometer Readout for Thermistor Probes gives you more accuracy in a limited temperature range as a thermistor readout. Thermistors are less fragile than PRTs and less likely to be impacted by mechanical shock. Thermistors are more sensitive to temperature, have faster response times, and come in many shapes for different applications.
    Typical accuracy of a 1504 is ±0.002 °C with a resolution of 0.0001 °C.
    Each Tweener is programmable to match a probe's constants for maximum linearity and accuracy. All probe constants and coefficients are programmed through simple, front-panel keystrokes. Temperature is displayed in °C, °F, K, or resistance in ohms.
    The 1504 accurately measures the resistance of the probe and then converts the resistance to a temperature value using its built-in algorithms.
    For convenience, the 1504 reads the common industrial grade IEC-751 or “385 ALPHA RTD without any programming. Enter the actual R0 and ALPHA of the individual probe for increased accuracy. For maximum accuracy, use the ITS-90 formulas. The Tweener accepts the subranges 4 and 6 through 11.
    ITS-90 formulas reside in the Tweener's firmware. If your probe has been calibrated for any of the above subranges of the ITS-90, you simply enter the coefficients directly into your Tweener.
    Each thermometer comes complete with an RS-232 interface for automation of temperature data collection, calibrations, or process control functions. An IEEE-488 interface is available as an option.
    The 1504 is calibrated digitally using the front-panel buttons. You never have to open the box to calibrate it. This calibration protocol further reduces the cost of this readout. It goes where you go and works the way you want it to.
    Software
    With 9934 LogWare, both Tweener models may be used for real-time data acquisition. Collect data and analyze it graphically or statistically. Additionally, Tweeners may be used as reference thermometers with MET/TEMP II software.
    Battery pack
    Want to take your Tweener on the road? Order Fluke Calibration's 9320A Battery Pack. Our battery gives you 36 hours between charges, allowing you to take your work wherever you need.
    Calibration choices
    Each Tweener and its accompanying probe (sold separately) have their own individual calibration reports. Overall system error can be calculated from the individual errors, rendering the added cost of system data unnecessary. However, for those requiring it, system data is available at two or more temperatures of your choice.
    Included Components
    1 - Extra Probe Connector
    1 - Power Cord
    1 - User Manual
    Terms & Conditions
    Please note estimated delivery time above. Contact us for details or if you have a delivery requirement. We ask for your patience while striving to ensure your shipment arrives quickly and accurately.
    Domestic Shipping
    FREE Standard Shipping on items OVER and less than 30lbs to continental U.S. Add for AK, HI, or PR. Please contact us for shipping rates to any overseas US territories including: Northern Mariana Islands, Guam, Puerto Rico, U.S. Virgin Islands and American Samoa.
    PO Boxes/APOs require USPS shipping and may therefore experience longer lead times
    6.25% Sales Tax for shipping to MA
    International Shipping
    Due to international voltage requirements, please ask us prior to purchasing to confirm your product will operate correctly in your country.
    Please contact us for shipping rates to any overseas U.S. territories.
    International customers are responsible for all shipping charges, including any duties or taxes.